          進口UE微壓控制器低報低聯鎖微壓型J400-4400-5mbar死區0.2-0.6mbar(Imported UE micro-pressure controller low report low interlock micro-pressure type J400-440 0-5mbar dead zone 0.2-0.6mbar )

           

          Imported UE micro-pressure controller low reporting low interlocking micro-pressure type J400-440 0-5mbar dead zone 0.2-0.6mbar technical parameters storage temperature -54 ~ 71 ℃    ambient temperature -40 ~ 71 ℃ Typical drift of set point does not exceed 1%    Set point repeatability Temperature switch: ±1% within adjustable range;Pressure switch type 126-376, 520-535 type: ±1% within adjustable range;Type 440-559: ±0.5% within theadjustable range Model 610-614: ±1.5% within the adjustable range    Shock resistance is tested by 15G, 10 millisecond cycle. Reproducible set point    vibration resistance is reproducible by 2.5G, 5~500HZ vibration test Set point    housing Die-casting aluminum alloy with epoxy resin coating. Gasket sealing. Clamping screw    Housing protection level plus option M900 can meet NEMA4X.IP65 requirements (waterproof electrical interface)    Switch output One, two or three single pole double Throw (SPDT) output. It can be set separately in the whole range. Type 531-534 is 50%; Type 520, 525, 535 is 30%; the switch can be connected as "normally open" or "normally closed    " Value 15 amps. 125/250/480 VAC    Weight approx.    3-7.5    pounds/2"NPTF    Temperature switch assembly The E series uses the same components as the F series. However, the range is limited due to the reference scale. Temperature bulb and capillary: 6 feet. 304 stainless steel in-line: 120 and 121 models: nickel-plated brass; optional 316L Stainless steel    filling 1BS type: solvent; 2-8 type: non-toxic oil    temperature dead zone laboratory conditions. F series is 1% in the full range. E series is 2%differential pressure indicator J400K. J402K with differential pressure display ( Option M210) Type 147-S157B. In the middle of the set point range; accuracy approximately 1.5% at 50%. 3% at both ends; indicator window is plexiglass material. Gasket sealed. Indicator within adjustable range On-the-spot adjustment on any set point. Accuracy up to ±1% Application The   400 series pressure switch is a multi-purpose series switch, especially suitable for when multi-point output and control are required. Two-point and three-point settings provide multi-point output, which can be used for alarm and shutdown, early warning and alarm, high/low limit and liquid level control functions.  All-weather series switches have a variety of micro switches and a variety of process interface options, so that the 400 series switches can meet various needs. Due to its own characteristics, the 400 series is widely used in protection and control, industrial process equipment and pumps, steam turbines, compressors, pulp and paper, water and sewage treatment and other industries. * Performance characteristics   · One, two or three switches Output, individually set for 100% of span over set point range.Epoxy coated and cast aluminum construction meets NEMA 4X standards   . Available in a variety of pressure components and materials   . Set with reference scale or Hex screw adjustment   . FM Approved J400 K系列差壓: J400K-127、J400K-128、J400K-129、J400K-130、J400K-131、J400K-132、J400K-133、J400K-134、J400K-135、J400K-136、 J400K-137、J400K-138、J400K-139、J400K-140、J400K-141、J400K-142、J400K-143、J400K-144、J400K-145、J400K-146、J400K-147、J400K-148、J400K-149、J400K-150、J400K-151、J400K-152、J400K-153、J400K-154 、J400K-155、J400K-156、J400K-157; J400K-232、J400K-233、J400K-234、J400K-235、J400K-236、J400K-237、J400K-238、J400K-239、J400K-240、J400K-241、J400K-242、J400K-243、J400K-244、J400K-245、J400K-246、J400K-247、J400K-248、J400K-249 、J400K-250、J400K-251、J400K-252、J400K-253、J400K-254; J400K-S127B、J400K-S128B、J400K-S129B、J400K-S130B、J400K-S131B、J400K-S132B、J400K-S133B、J400K-S134B、J400K-S144B、J400K-S145B、J400K-S146B、J400K-S147B、J400K-S148B、J400K-S149B、J400K-S150B、 J400K-S151B、J400K-S152B、J400K-S153B、J400K-S154B、J400K-S155B、J400K-S156B、J400K-S157B; 

           

           

          注:除進口UE微壓控制器低報低聯鎖微壓型J400-4400-5mbar死區0.2-0.6mbar,更多United Electric(UE)型號歡迎電話或在線聯系。

           

           

          本文出自 深圳沃德科技官網,轉載時請注明出處及相應鏈接。

          本文永久鏈接:http://www.whkfq.net/zs/ue68807.html

          国产视频